Permanent Light Function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in add-
ition to the simple "ON"/"OFF" function:
Sensor operation
1) Switch light "ON" (when floodlight is "OFF"):
Switch "OFF" and "ON" once.
LEDs stay "ON" for the period selected.
2) Switch light "OFF" (when floodlight is "ON"):
Switch "OFF" and "ON" once.
Floodlight goes out or switches to sensor mode.
Operation and Maintenance
The unit is not suitable for special burglary alarm
systems since it lacks the tampering protection pre-
scribed for this purpose. Weather can affect operation
of the sensor-switched LED floodlight. Strong gusts
of wind, snow, rain and hail may cause the light to
Technical specifications
Sensor-switched LED floodlight
XLed 10 XLed 25
Wattage:
10 LED's, approx. 25 W
Light colour:
approx. 4000 kelvin (warm white)
Luminous flux:
960 lumens
Additional switching capacity:
Life of LED's:
up to 50,000 hrs.
(for 3 hrs./day approx. 45 years)
Angle of coverage:
240° with sneak-by guard
Projected area
250 cm
2
+ 103.36 cm
Swivelling range of
sensor unit:
± 80°
Swivelling range of housing:
200° vertically
270° horizontally
Time setting:
5 sec. – 15 min.
Twilight setting:
2 – 2000 lux
Brightness control:
10% basic brightness (approx. 3 W) 10% basic brightness (approx. 6 W)
Permanent light "ON":
4 hrs., selectable
Dimensions (h x w x d)
205 x 200 x 220 mm
Weight:
2200 g
Temperature range:
-20 °C to + 50 °C
IP rating:
IP 44
Protection class:
I
Manual override
1) Activate manual override:
Turn switch "OFF" and "ON" twice. The floodlight is
set to stay "ON" for 4 hours (red LED lights up behind
the lens). Then it returns automatically to sensor
mode (red LED "OFF").
2) Deactivate manual override:
Switch "OFF" and "ON" once. Floodlight goes out or
switches to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
come "ON" when it is not wanted because the sensor is
unable to distinguish sudden changes in temperature
from sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).
25 LED's, approx. 60 W
approx. 4000 kelvin (warm white)
2120 lumens
Filament bulbs, 800 W max. at 230 V AC
Fluorescent tube, 400 W max. at cos ϕ = 0.5,
inductive load at 230 V AC
Fluorescent lamps, low-energy lamps,
LED lights with electronic ballast at 230 V AC,
4 x 60 W each max., C ≤ 88 µF
up to 50,000 hrs.
(for 3 hrs./day approx. 45 years)
240° with sneak-by guard
2
420 cm
2
+ 103.36 cm
± 80°
200° vertically
270° horizontally
5 sec. – 15 min.
2 – 2000 lux
4 hrs., selectable
300 x 200 x 220 mm
2960 g
-20 °C to +50 °C
IP 44
I
- 12 -
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com

Troubleshooting

Malfunction
Sensor-switched LED floodlight
without power
Sensor-switched LED floodlight
will not switch "ON"
Sensor-switched LED floodlight
will not switch "OFF"
Sensor-switched LED floodlight
keeps switching "ON" and "OFF"
Sensor-switched LED floodlight
switches "ON" when it should not
Declaration of conformity
This product complies with Low Voltage Directive
2006/95/EC, EMC Directive 2004/108/EC as well as
RoHS Directive 2002/95/EC.
2
Functional warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition
and proper working order.
The warranty period is 36 months and starts on the
date of sale to the consumer. We will remedy defects
caused by material flaws or manufacturing faults.
The warranty will be met by repair or replacement of
defective parts at our own discretion. The warranty
shall not cover damage to wear parts, damage or
defects caused by improper treatment or mainten-
ance. Further consequential damage to other objects
is excluded.
Cause
Remedy
Fuse faulty, not switched "ON",
Fit new fuse; switch "ON"
break in wiring
mains switch; check wiring
with voltage tester
Short circuit
Check connections
Twilight control set to night-time
Adjust setting
mode during daytime operation
Mains power switch "OFF"
Switch "ON"
Fuse faulty
Fit new fuse, check connection
if necessary
Detection zone not properly
Re-adjust
targeted
Continuous movement in the
Check zone and readjust if
detection zone
necessary or apply shroud
Animals moving in the
Tilt sensor higher or apply
detection zone
specific shrouds; adjust zone,
or apply shrouds
Wind is moving trees and
Change detection zone
bushes in the detection zone
Cars in the street are being
Change detection zone
detected
Sudden temperature changes
Adjust detection zone or install
due to weather (wind, rain,
in a different place
snow) or air expelled from fans,
open windows
Sensor-switched LED floodlight
Mount sensor-switched LED
is moving (swaying) due to gusts
floodlight on a firm surface
of wind or heavy rain.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well-packed with a
brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate
Service Centre.
Repair service:
Our Customer Service Department
will repair faults not covered by war-
ranty or after the warranty period.
Please send the product well packed
to your nearest Service Centre.
- 13 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xled 10

Tabla de contenido