Greenlee DM-200 Manual De Instrucciones página 16

Multímetros digitales
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy
DC Voltage
Range
249.9 mV
2.499 V
24.99 V
249.9 V
1000 V
Frequency (DM-210 only)
Function
249.9 mV
2.499 V
24.99 V
249.9 V
1000 V
Ohms
µA
mA
A
* d refers to the least significant digit (the number in the rightmost position).
Resistance
Range
249.9 Ω
2.499 kΩ
24.99 kΩ
249.9 kΩ
2.499 MΩ
25.00 MΩ
16
Accuracy
± (0.3% + 0.4 mV)
± (0.5% + 0.002 V)
± (0.5% + 0.02 V)
± (0.5% + 0.2 V)
± (1% + 4 V)
Sensitivity (Sine RMS)
3 V
4 V
10 V
80 V
550 V
500 mV
900 µA
120 mA
7 A
Accuracy
± (0.6% + 0.8 Ω)
± (0.4% + 0.005 kΩ)
± (0.4% + 0.02 kΩ)
± (0.4% + 0.2 kΩ)
± (0.4% + 0.002 MΩ)
± (1.0% + 0.04 MΩ)
Input Impedance
10 MΩ, 15 pF nominal
Accuracy
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
± (0.05% + 4 d)*
Open Circuit Voltage
Range
30 Hz to 30 kHz
30 Hz to 1 kHz
30 Hz to 200 kHz
30 Hz to 30 kHz
30 Hz to 1 kHz
< 0.4 VDC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dm-210

Tabla de contenido