Accuracy
Capacitance (DM-210 only)
Range
2.499 nF
24.99 nF
249.9 nF
* Accuracies are for film capacitors (capacitors with negligible dielectric absorption).
** Accuracy is specified for ≥ 0.25 nF.
Wireless Electric Field Detection (DET)
Typical Voltage
30 V to 150 V
60 V to 300 V
100 V to 480 V
300 V to 700 V
More than 500 V
* Bar graph indication and tone are proportional to signal strength.
Temperature (DM-210 only)
Range: –4 °F to 572 °F
Accuracy: ± (6 °F + 6 d)
* d refers to the least significant digit (the number in the rightmost position).
Note: The accuracy information is for the meter only; see the information sheet provided with
your temperature probe (purchased separately) for its accuracy.
Diode Test
Measuring Range: 2.000 V
Test Current (Typical): 1 mA
Open Circuit Voltage: Less than 1.8 VDC
Continuity
Tone indicates continuity. The threshold is between 20 Ω and 150 Ω.
Accuracy*
± (6.0% + 0.045 nF)**
± (2.8% + 0.04 nF)
± (1.0% + 0.4 nF)
Bar Graph Indication*
Range
2.499 µF
25.00 µF
• •
• • •
• • • •
• • • • •
DM-200 • DM-210
Accuracy*
± (1.5% + 0.004 µF)
± (2.0% + 0.04 µF)
Frequency Range
50 Hz to 60 Hz