2.10 Energy-saving function: the lower limit of cooling temperature and upper limit of heating temperature of any
indoor unit can be set to achieve energy-saving effect. Energy consumption can also be reduced by limiting the
operating capacity of the outdoor units.
2.11 Alarm management and setting function- It supports checking and exporting the failure data of a unit.
It can also be set to perform functions like automatic email sender, pop-up window, beeping and sounding off
other alarms when the failure alarm rings.
2.12 Threshold alarm management and setting function- It supports the threshold alarm function for setting any
parameter. As an addition to the common fault alarm, it can also set the alarm prompt to automatically send
emails, pop Windows, beeping and other alarm prompts.
2.13 Equipment linkage function supports th2.e setting of AHU binding linkage indoor unit. It recognises the linkage
between any 'turn ON 'or 'turn OFF' indoor unit or all indoor unit 'on/off' mode in the set area. It also recognises
the automatic switch function of AHU.
2.14 Daylight saving time function sets the daylight saving time and automatically adjusts the amplitude as required.
After the adjustment, the schedule will be adjusted automatically. There is no need to reset the schedule.
2.15 Timing task function allows non-administrator users to set the timing task to be executed once. It also sets a
specific time for the switching machine, temperature, wind speed and mode of a single indoor unit/indoor units in
the zone/all indoor units.
2.16 Third-party device management function supports the access of third-party devices controlled by I/O through
Carrier gateway such as lighting, fans, curtains, etc. It implements the control functions of the proposed building
automation.
2.17 Network setting function supports the local network, WIFI access and LAN access setting.
2.18 The history and logging function records the operation of the device and the operation of the user. The administrator
can query or export the information. It facilitates the administrator about the system management.
2.19 Device data backup and recovery function- The configuration of the current system can be backed up by the
external USB flash disk. The configuration files that have been exported can be restored to the device.
2.20 Advanced setting function- Advanced setting refers to other ancillary settings like switching temperature unit,
region and language.