Beninca KER Manual Del Usuario página 10

Ocultar thumbs Ver también para KER:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
TW
The maximum duration of the opening and closing operation is adjusted.
It should be preset at around 4sec more compared to the actual stroke time of the
system.
The adjustment varies from 3 sec minimum to 180 sec maximum.
TCA
The automatic closure time can be adjusted.
The adjustment varies from 3 sec minimum to 180 sec maximum.
With TCA trimmer entirely turned clockwise, the LED DL2 (green) switches off
and the TCA is deactivated.
By moving all DIPs to ON, the control unit switches to the SERVICE MAN mode.
The PHOT input takes the CLOSE Button function (connect the push-button with a N.O.
contact).
The PP input acts as OPEN Button (connect the push-button with a N.O. contact).
The SWO and SWC inputs are disabled.
During the entire operation, the OPEN/CLOSE push-buttons must be kept pressed. When the
STOP input opens, the motor stops.
By pressing the OPEN/CLOSE buttons simultaneously, the motor stops.
When DIP1 is moved to ON, the card indicates the torque applied at that moment through a
number of flashes (from 1 to 4) of the DL2 green LED, followed by a 3 sec interval.
The maximum torque is indicated with the DL2 green LED with fixed light.
To increase the torque, press the P1 key. The DL2 LED changes the number of flashes to indicate
the selected torque value.
Once the desired torque is selected, to learn this setting move the DIP1 to OFF.
The KER control unit is equipped of a built-in radio module for the reception of variable code,
with 433.92 MHz frequency.
To use a remote control, its code must be stored in memory. The memorisation procedure is
shown hereunder. Up to 64 different codes can be stored in the memory of the device.
By pressing the P1 key, the control unit enters the radio self-learning phase: the red DL1 LED
flashes 1 time per second, awaiting for the key to be matched to the Step-by-Step function;
Once the key is learned, exit from the programming mode;
By pressing the P1 key twice, the red DL1 LED flashes two times per second and enters the
learning mode of Channel 2, radio/pedestrian*.
Once the key is learned, exit from the programming mode.
To exit the programming mode without learning any radio control code, press P1 key until the red
DL1 LED returns flashing in the "mains" power supply mode (see LED diagnostics, page 7).
* NOTE: Keep in mind that if DIP5 is OFF, the matched key acts as pedestrian key (opening for around 7
seconds), otherwise, with DIP5 to ON, the matched key operates as 2nd channel on the SCA output.
To reset the receiver memory, press P1 and P2 keys simultaneously and keep them pressed for
around 10 seconds (during this time-lapse, both DL1 and DL2 LEDs flash rapidly).
After ten seconds, the two LEDs remain switched on with fixed light. Release the push-buttons.
When the LEDs return to the initial configuration, this means that the control unit has performed
the resetting of the memory.
10
TRIMMER OPERATIONS
SERVICE MAN MODE
TORQUE REGULATION (DIP1:ON)
RADIO LEARNING (DIP1:OFF)

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido