^ Remove the oven shelf supports and
lower the top heat heating element.
^ Remove the roof liner (depending on
model).
^ Unscrew the vapour outlet screws.
^ Remove the vapour outlet.
It is no longer required.
^ Some models also have a perforated
panel fitted underneath the vapour
outlet. It must be removed before fit-
ting the catalyser as it is no longer re-
quired.
All manuals and user guides at all-guides.com
Service engineer fitting instructions
^ Press back the oven ceiling insula-
tion.
^ Gently compress the fitting guide b
and put in place.
Then release the fitting guide and in
doing so press back the insulation.
Ensure that the insulation is fully
pressed in by the fitting guide.
Do not allow the insulation to get
trapped by the fitting guide.
The fitting guide remains in the ap-
pliance once fitted.
For reasons of hygiene, the area
around the catalyser should be thor-
oughly vacuum cleaned to ensure
that insulation fibres cannot get into
the oven cavity.