Thermal
Alignmentof air
power of the
shutter (mm)
burner (kW)
9,0
H = 16
7,0
H = 14
5,0
H = 14
3,5
H = 14
9,0
H = 12
7,0
H = 8
5,0
H = 8
3,5
H = 10
9,0
H = 14
7,0
H = 12
5,0
H = 12
3,5
H = 12
9,0
H = 16
7,0
H = 14
5,0
H = 14
3,5
H = 14
9,0
H = 22
7,0
H = 20
5,0
H = 20
3,5
H = 20
9,0
H = 21
7,0
H = 19
5,0
H = 19
3,5
H = 19
9,0
H = 18
7,0
H = 16
5,0
H = 16
3,5
H = 16
8.3. Installation
The stove may be connected to the gas installation or to the gas cylinder only by a person authorized
to perform installation services. Conversion of the stove to another type of gas must be carried out
by an authorized installer
• After unpacking make sure that the unit does not show any visible damage. If the unit has been dama-
ged during transport, do not connect it!
• The protective foil must be removed from the unit before the start-up. Wash the outer surfaces with
a cloth wet in warm water and degreasing agent, and then dry them out. Do not use any agents that
could scratch the surface.
• Facilities in which gas appliances are to be installed must comply with the installation regulations of
the country, in which they are to be installed.
• The stove should be positioned in a well-ventilated room. It is necessary to ensure a unblocked inflow of
air to the stove (it is necessary during the gas combustion process) as well as safe exhaust discharge (do
not place the stove in recessed parts, do not block it with high appliances/cabinets aside, etc.). When the
kitchen is placed against a wall, the minimum distance should be as follows:
• from a non-flammable wall according to installation possibilities,
• from a protected flammable wall, i.e. a wall made of flammable materials, but rendered or protected
Setting the burner shutter
Gas pressu-
Type of gas
re (mbar)
G27
20
G27
20
G27
20
G27
20
G25.3
25
G25.3
25
G25.3
25
G25.3
25
G20
25
G20
25
G20
25
G20
25
G20
20
G20
20
G20
20
G20
20
G30/31
30
G30/31
30
G30/31
30
G30/31
30
G30/31
37
G30/31
37
G30/31
37
G30/31
37
G30/31
50
G30/31
50
G30/31
50
G30/31
50
- 55 -