Menu Settings - Uline SCOUT H-9560 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The User Menu allows the customizing of scale settings.
MENU NAVIGATION
SUB-MENUS
Tare
Menu
Exit
Yes
No/Back
Exit
*Available units may vary by local regulations.
**Available settings may vary by local regulations.
When the security switch is in locked position
(See Figure 7), the menu settings are affected as follows:
• External calibration function is hidden.
• The readability will be reduced by a factor of 10
or brackets will be displayed around the last digit,
depending on the model.
• The auxiliary graduation menu will be locked.
• Units are locked to the current setting.
• Stable range locked to 1d.
• AZT locked to 0.5d.
PAGE 9 OF 53

MENU SETTINGS

C.A.L
Long Press –
Reset
Enter Menu
Auxiliary
Graduation*
Short press –
Accept
Filter
Span
Short press –
Go Next/
Prev. menu
AZT
Short press –
Lin
Exit menu
StableRange
Backlight
Auto Tare
Auto Off
End
End
End
NOTE: Additional sub-menus may be available
if Interface Options are installed.
S.E.T.U.P
M.O.D.E
Reset
Yes/No
Weighing
On/Off
Counting
Low/Med/High
Percent
0.5/1/3/Off
Check
0.5/1/2//5
Totalize
Off/On/Auto
Density
Off/On/On-acc
Hold
Disp/Peak/Off
Off/1/5/10
End
• Zero range forced to 2%.
• Filter level is locked to current setting.
• Stable only when Print menu locked ON.
• Continuous/Interval print cannot be selected.
Figure 7
Unlocked
U.N.I.T*
E.N.D
Reset
Yes/No
g
kg
On/Off
ct
oz
ozt
On/Off
dwt
lb
grn
On/Off
hkt
sgt
twt
On/Off
t
tola/tical
On/Off
On/Off
End
End
Locked