All manuals and user guides at all-guides.com
enGliSH
teMperature
1. Insert K-type thermocouple with adapter into the VΩ
jacks (observe polarity markings on thermocouple and meter), and
rotate function selector switch
note: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SEL" button
appropriate icon (either °F or °C ) appears on the display. Default
temperature scale may be changed by powering on the meter with
the "HOLD" button
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
remove thermocouple before switching meter to other
measurement functions.
the thermocouple included with the original purchase
is suitable for temperatures below 356°f / 180°c only. to
measure higher temperatures, a k-type thermocouple
with the appropriate measurement range should be used.
Bar GrapH
The Bar Graph is an analog representation of the measurement. It responds
to the measurement approximately 3-5 times faster than the digits in the
digital display which, in certain circumstances, may allow the user to have
a clearer view of quick changes in the property being measured. In any
given range the bar graph scales from zero on the left hand side to the
maximum value of the range on the right hand side of the display.
16
MM700-1390112ART.indd 16
Dwg Name: MM700-1390112ART
Dwg No: 1390112
ECO No: 20617
Pkg Dwg Ref: 1290186
Color Reference: N/A
operatinG inStructionS
to the Temperature
2
once. Ensure that the
11
depressed.
11
Adapter
RED
Probe
BLACK
K-Type
Thermocouple
with Adapter
Bar graph
Rev: E
and COM
5
4
setting.