Dometic AH-Elite Control Manual Del Usuario página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
AH-Elite Control
No.
Description
P-9
Display Brightness
Control
P-10
Temperatures in Fahren-
heit or Celsius
P-11
Reserved for future use
P-12
Reverse fan speeds
during heat mode
P-13
Reverse-cycle heating
or electric-heat-only
option installed
P-14
Fan-motor type: Split
Capacitor or Shaded
Pole
P-15
Reset memorized
programming defaults
P-16
Hydronic water valve
forced open
P-17
Temperature differential
P-18
Air filter clean-
ing/replacement timer
setting (x10 hours)
P-19
Air filter clean-
ing/replacement value
(x10 hours) & reset
P-20
CAN-bus unit ID
P-21
CAN-bus group ID
EN
Defaults
Factory
15
F
rEF
nor
SC
nor
nor
15 °F
(8.33 °C)
0
0
1
2
0
2
0
Programming the control unit
Range
Custom
4 (dimmest) – 18 (brightest)
F = Fahrenheit
C = Celsius
nor = normal fan operation
rEF = reversed fan in heat mode
nor = reverse-cycle heating
ELE = electric heater installed
SC = Split Capacitor fan motor
SP = Shaded Pole fan motor
rST =reset defaults
nor = normal
OPn = valve forced open
nor = normal operation
5 °F – 25 °F (2.8 °C – 13.9 °C)
0 = timer disabled
10 – 250 (100 – 2500 hours)
Displays the elapsed time (in
hours x10) since the timer was
started or reset. (The setting can
only be reset to 0.)
0 – 255 (Each control on a
CAN-bus network must have a
unique Unit ID.)
0 – 255 (The address for the con-
trol's CAN-bus network group
should be different from any
CAN-bus Unit ID.)
5
21

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido