Fig. 4b
3. If a rear outlet is used, the upper middle part of the
heatshield is removed. This is done by cutting off 4 metal
studs (cutters should be used).
Assembly of the fl ue pipe
The product is assembled for a top outlet as standard.
Fig. 5 Assembling the fl ue pipe
A
B
1. Attach the gasket (B) to the end of the fl ue pipe(A). Then
insert the fl ue pipe into the outlet (C).
Flue pipe is installed in the same way for top and rear outlet.
82
4.3 Assembly with an external air
supply (optional extra - 51047509)
Fresh air supply
The air used for combustion in any well-insulated house needs
to be replaced. This is particularly important in houses with
mechanical ventilation. Such replacement air can be procured
in several ways. The most important thing is to supply the air
to the room where the stove is placed. Place the outside wall
valve as close to the stove as possible and make sure that it
can be closed when the stove is not in use.
For the fresh air supply connection, follow the national and
local building regulations.
Important! Ensure that air vents in the room where the
fi replace is located are not blocked.
Closed combustion system
Use the stove's closed combustion system if you live in recently
built, airtight dwellings. Connect the external combustion air
through a ventilation pipe through the wall or the fl oor.

Air supply

The amount of combustion air for Jøtul's products is approximately
20-40 m
/h. The outside air connection may be fi tted directly to
3
the Jøtul F 200/F 205 through:
the bottom
through a fl exible supply hose from the outside/chimney
(only if the chimney has its own duct for external air) and to
the product's outside air connector.
Fig. 6a Through an outside wall
C