Miele F 2412 Vi Instrucciones De Instalación Y Funcionamiento página 108

Tabla de contenido

Publicidad

Filtro de agua
NSF System Trade name: WFS200MF & WFS210MF
NSF Replacement Cartridge No: WFC100MF (for WFS200MF) & WFC110MF (for WFS210MF)
System tested and certified by NSF International against NSF/ANSI
Standard 42, 53, 401 for the reduction of the claims listed below.
This system has been tested according to NSF/ANSI 42, 53, 401 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, 401.
ubstance
Chlorine aste and
dor
hloramine
articulate, Class I
particles ≥0.5 to <1 μm
trazine
enzene
arbofuran
p- ichlorobenzene
Lead pH
6.5
Lead pH
8.5
Mercury pH
6.5
Mercury pH
8.5
urbidity
thylbenzene
oxaphene
sbestos
yst
Meprobamate
Atenolol
Carbamazepine
108
Performance Data Sheet
Model: Miele 07134220
Use Replacement Cartridge 07134220
Influent hallenge
Average eduction
concentration
2.0 mg/L ± 10%
3.0 mg/L ± 10%
at least 10,000
particles/mL
0.009 mg/L ± 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
0.225 mg/L ± 10%
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
11 ± 1 NTU
2.1 mg/L ± 10%
0.015 mg/L ± 10%
7
8
10
to 10
fibers/L;
fibers greater than
10 μm in length
minimum 50,000/L
400 ng/L ± 20%
200 ng/L ± 20%
1,400 ng/L ± 20%
Reduction
requirement
97.2%
≥ 50%
97.2%
N/A
>99.9%
≥ 85%
>94.4%
N/A
>96.8%
N/A
>98.8%
N/A
>99.8%
N/A
98.8%
N/A
97.9%
N/A
>96.5%
N/A
>96.6%
N/A
99.1%
N/A
>99.9%
N/A
>93.3%
N/A
>99%
99%
99.99%
99.95%
>95.2%
N/A
>95.6%
N/A
>98.6%
N/A
Max
ermissible roduct
water concentration
N/A
0.5 mg/L
N/A
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.5 NTU
0.7 mg/L
0.003 mg/L
N/A
N/A
60 ng/L
30 ng/L
200 ng/L

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

F 2802 viF 2812 viF 2902 viF 2912 vi

Tabla de contenido