WATER DRAIN CONNECTION

To carry out this operation, proceed as follows.
Connect the mains water pipe (A) to the appliance's connection
pipe (C).
The appliance's drain line is fitted with the plug (B) allowing
discharge of the waste deposited.
C
A

ELECTRICAL CONNECTION

Caution - warning
The connection must be made by authorised, skilled per-
sonnel, in accordance with the relevant legal require-
ments, using appropriate and specified materials.
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply as follows.
1- If not already present, install an automatic circuit-breaker
(B), close to the appliance, with the following characteristics.
– Thermal breaker device set at 12 A
– Differential breaker set at 30 mA
– Class B or C (IEC 898)
2- Undo the screws and remove the side panel (A).
3- Connect the automatic circuit-breaker (B) to the appliance's
terminal board (C) and to the electrical mains supply, in ac-
cordance with the electrical system diagram provided at the
back of the manual and using a cable with the following
characteristics.
– Weight: ≥ than H05RN-F type (designation 245 IEC 57)
– Temperature of use: ≥70°C.
Important
7/11
When connecting, take care over the connection of
the neutral and earth wires; if they are not connected
correctly, the burner does not light.
4- Replace the panel (A) and retighten the screws when the
operation is complete.
C
B

CONVERSION OF GAS SUPPLY

The manufacturer has tested the appliance with its own mains
IDM-39614000500.tif
gas, identified by the sticker applied to the nameplate. If the
type of gas to be connected is different from that used for
testing, proceed as follows.
1- Turn off the gas supply tap (A).
2- Change the burner nozzle (see page 13).
3- Remove the testing gas sticker from the dataplate (B) and ap-
7/12
ply the new one to identify the gas being used.
4- Remove the sticker from the nameplate (C) and apply the new
one to identify the gas being used.
Important
On completion of the operation, make sure that there
are no gas leaks or malfunctions.
C
B
- 11 -
B
A
IDM-3960320210.tif
A
IDM-3960320220.tif