Adjustments; Checking Gas Pressure - Angelo Po FC 611 G Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TESTING THE APPLIANCE
Important
Before it is put into service, the system must be tested
to check the operating conditions of every single
component and identify any malfunctions. In this
stage, it is important to check that all health and safe-
ty requirements have been complied with in full.
To test the system, make the following checks:
1- turn on the gas supply tap and check that the connections
are tight;
2- turn on the master switch to check the electrical connection;
RECOMMENDATIONS FOR

ADJUSTMENTS

Important
Before making any type of adjustment, activate all the
safety devices provided and decide whether staff at
work and those in the vicinity should be informed. In
particular, turn off the gas and water supply taps, cut
off the electricity supply using the master switch
and prevent access to all devices which might
cause unexpected health and safety hazards if
turned on
.
Do not tamper with the safety devices in the points
sealed and marked with paint.
IT
GB
DE
FR
ES
English
3- check that the mains gas is the same as that used for com-
7/14
missioning of the appliance, and carry out the conversion
procedure if necessary (see page 11);
4- check that the gas pressure conforms to the values stated in
the table at the back of the manual (see page 12);
5- check that the safety devices are working correctly;
6- carry out a cooking cycle without food to ensure that the ap-
pliance is operating correctly.
After testing, if necessary instruct the user in all the skills nec-
essary for putting the appliance into operation in conditions of
safety, in accordance with legal requirements.
ADJUSTMENTS

CHECKING GAS PRESSURE

To carry out this operation, proceed as follows.
8/1
1- Turn off the gas supply tap (A).
2- Remove the side panel (B).
3- Take out the screw (C).
4- Connect the pressure gauge (D) to the pressure connection.
5- Turn the gas supply tap (A) back on.
6- Switch on the appliance (see page 5) and carry out a cooking
cycle without food at the maximum temperature.
7- Check that the pressure gauge reading complies with the val-
ues (see table at back of manual).
8- Switch off the appliance and turn the gas supply back off (A).
9- Disconnect the pressure gauge and replace the screw (C).
10- Replace the side panel (B).
- 12 -
B
C
D
A
8
8/2
IDM-3960320110.tif

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fc 1011 g

Tabla de contenido