PARAMETER
VALUE
RX
START
APCH
STOP
PROS
CHIU
APRE
INVE
FOT1
NO
HOOK
MASK
APCH
FOT2
APCH
NO
HOOK
MASK
FT.TE
0.1"-2.0"
NO
COS1
NO
AP
APCH
CH
COS2
NO
AP
APCH
CH
CO.TE
NO
RESI
FOTO
ENCO
NO
INTRM
EN.1C
EN.2C
SUBMENU
DESCRIPTION
Receiver mode
Channel 1 = START
Channel 2 = PARTIAL START
Channel 1 = OPEN
Channel 2 = CLOSE
Stop command function
Stop then resume
Close then hold
Open then hold
Stop then invert
Photocell 1 mode
No function
Anti-dragging function
P.AP.F
0-100%
Enabled in closing and with masked operation
Enabled in opening and closing
Photocell 2 mode
Enabled in opening and closing
No function
P.AP.F
0-100%
Anti-dragging function
Enabled in closing and with masked operation
Photocell test enable
Function disabled
Safety ribbon 1 mode
No function
Enabled opening
Enabled opening and closing
Enabled closing
Funzione costa sensibile 2
No function
Enabled opening
Enabled opening and closing
Enabled closing
Ribbon type and test
Mechanic - no test
Resistive
Optical with test
Encoder enable
No function
Intermediate positions
1-channel encoder
2-channel encoder
- 50 -
DEFAULT
CHAPTER
MEMO
20
START
19
PROS
11
NO
11
APCH
P.AP.F
= 0%
11.2
NO
12.3
NO
12.3
NO
12.3
NO
17-18
NO