Problem
The appliance
is not working
Oil is spilling
over the rim
The appliance
is working but
the POWER
indicator does
not light up
The POWER
indicator lights
up but the
appliance does
not heat up
The basket
cannot be
removed from
the oil reservoir
www.KALORIK.com
Cause
Magnetic plug not
properly fitted
Control panel
assembly not
installed correctly
Appliance not
plugged in
Wall outlet not
energized
Malfunctioning
appliance
Overheated oil or
appliance
Overfilled oil reservoir
Overfilled basket
Damaged POWER
indicator
Preheat time too
short
Malfunctioning
appliance
Basket handle not
attached properly
Solution
Connect the magnetic plug to the
electrical outlet before connecting
the plug to the wall outlet
Install the control panel assembly
correctly by pushing it completely
down so that the safety switch is
activated
Insert the plug into the wall outlet
Check fuses and circuit breaker
Unplug the appliance from the wall
outlet and contact qualified personnel
to check and repair the appliance
Unplug the appliance from the wall
outlet and allow the appliance / oil to
cool down. Then press the reset switch
closest to the safety switch.
Unplug the appliance from the wall
outlet and allow the appliance / oil to
cool down. Then, remove excess of oil
Lift out the basket by its handle and
hang it onto the basket hook into the
notch. Remove excess of food with
suitable utensils
Unplug the appliance from the wall
outlet and contact qualified personnel
to check and repair the appliance
Allow the appliance to preheat for a
longer time
Unplug the appliance from the wall
outlet and contact qualified personnel
to check and repair the appliance
Remove fried food using suitable
utensils and allow the appliance / oil
to cool down completely before
removing the basket