11.3
SMOKE TEMPERATURE EXCESS ALARM
It goes off when the probe detects a smoke temperature higher than 270°C. Therefore
the control shows the following message (see drawing D92):
During the alarm state, the stove or insert will be in the turn-off stage.
11.4
DAMAGED SMOKE EXTRACTION FAN ALARM
It goes off when the smoke extraction fan breaks down. If this happens, the stove or
insert stops and the control will show up the following alarm (see drawing D93). Right
after, the turn-off stage will be immediately activated.
To deactivate the alarm press button 3 and the stove or insert will come to the normal
state after doing the final cleaning.
11.5
IGNITION FAILURE ALARM
In case of ignition failure (after 20 minutes at least) the control will show up an alarm as
follows (see drawing D94).
To deactivate the alarm press button 3 and the stove or insert will come to the normal
state after doing the final cleaning.
11.6
SWITCHING-OFF FAILURE DURING WORKING PHASE
If the flame extinguishes during the working stage and the smoke temperature goes
lower than the minimum working threshold, the alarm does go off and the turn-off stage
will be immediately activated (see drawing 95).
To deactivate the alarm press button 3 and the stove or insert will come to the normal
state after doing the final cleaning.
11.7
THERMAL ALARM
If in working phase the thermal security alarm is shows up (see drawing D96), the turn-
off stage will be immediately activated. This alarm means an overheating of the internal
part of the tank, this device blocks the operation of the machine. The restart needs to
be done manually by an authorised technician.
The restoration of the 90ºC safety device is not included in the warranty unless the
technical assistance centre demonstrates a faulty component.
11.8
COMBUSTION CHAMBER PRESSURE ALARM
It happens when there is a pressure change in the combustion chamber (door open, dirt
registers, air returns...). The electronic pressure switch blocks the working of the stove
or insert and shows the alarm. After that the turn-off stage will be immediately activated
(see drawing D97).
11.9
LACK OF PRIMARY AIR INTAKE FLOW ALARM
Your stove or insert has a flow sensor placed inside the primary air suction pipe. It
detects the proper circulation of combustion air and the smoke exhaust. In case of
insufficient air inlet (due to incorrect smoke outlet or improper air intake), the sensor
sends a "block" signal. After that the turn-off stage will be immediately activated (see
drawing D98).
11.10
WORM GEAR FAILURE ALARM
The control of the fuel amount to the stove or insert is automatically made through
the electronic programming. It goes off in the event of the endless breakdown. If this
happens, the stove or insert stops and the display will show up the following alarm.
Right after, the turn-off stage will be immediately activated (see drawing D99).
If this alarm appears you must contact the technical support service.
11.11
FLOW SENSOR ANOMALY SENSOR
In case of anomaly of the flow sensor, placed on the primary air aspiration tube, a blockage signal is send to the
stove or insert and right after the turn-off stage will be immediately activated. (see drawing D100).
If this alarm appears you must contact the technical support service.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
ALARM 3
TEMP.
SMOKE
MENU
ALARM 5
FAILURE
IGNITION
MENU
ALARM 7
SECURITY
THERMAL
MENU
ALARM 9
FLOW
ALARM
MENU
43
ALARM 4
FAILURE
ASPIRATION
MENU
D92
D93
ALARM 6
NO PELLET
MENU
D95
D94
ALARM 8
FAILURE
PRESSURE
MENU
D97
D96
ALARM b
ENDLESS
ERROR
MENU
D98
D99
ALARM
FAILURE
FLOWMETER
MENU
D100
RADIOFREQUENCY SERIES