Numbers in parentheses ( ) refer to the exploded view
drawing on page 11.
FLUID SECTION
1. Follow the Pressure Relief Procedures and Warnings
on page 4.
2. Disconnect the air and fluid lines, remove the pump
from its mounting, and place it on a shop bench. A vise
will be necessary for this procedure.
3. Mount pump using the integral air motor mounting
pads. Use all four holes!
4. Remove the outlet (36B) and siphon (36A) manifolds
from the pump by loosening/ removing the sanitary
type clamps (37). During removal, capture the sanitary
seals (35) as the manifolds come away from the pump.
Inspect the sanitary seals and replace if damaged or worn.
5. Remove the four socket head cap screws (22) and
washers (21) that secure the output block (20) to the
dynamic chamber (13).
6. Gently wiggle the fluid section (block with ball cages
and flange adapters attached) until it is free from the
piston seal and place on the work bench.
12
SECTION 5.3 – DISASSEMBLY
Step 7 is required only for maintenance on balls and seats.
7. Remove the four socket head cap screws (28) that hold
each flange adapter (27) and ball cage (26) to the output
block. Carefully remove the flange adapters and ball
cages taking care not to drop or damage the ball (25) or
the seat (24) inside. Note the seat orientation.
The upper and lower ball cages and flange adapters are
identical. Each ball cage has an arrow indicating the proper
flow direction. Also, the PTFE o-rings (23) should be replaced
when the fluid section is rebuilt.
23
Remove fluid section
as a unit
Items 21 & 22
NOTE
28
27
26
25
24
20