6.3
PLUMBING SYSTEM
Connection to the plumbing system and the
plumbing system must be in compliance with
current national laws and standards, and realized
1. Make the water connections to the boiler body
as described on the datasheet in the Product
Booklet.
2. Make sure that all the control and safety
devices including those supplied with the
stove are installed correctly (safety and heat
exhaust valves).
You MUST NOT insert devices that completely
close the heating system (zone valves). For safety
reasons, the pump must ALWAYS run while the
stove is on, dispersing the heat produced. If there
is too much ambient heat, reduce the volume of the
IN order to service the plumbing connections for
easily accessing it:
• Open the door (1).
• Unclip the control panel connection cable (2)
•
Top. (3)
• Pull the top upwards (4)
• Unscrew the screws and remove the rear
backrest (5)
• Remove the side panels (6-7)
32
INSTALLATION
6
00 477 6270 - 02/2018
2
1
3
4
7
5