* Place the ice dispenser on a firm level surface at counter top height.
* Turn the leg adjusters to level the unit in both the left-to-right and front-to-rear directions
(tilt limit: within 1 cm).
6. ELECTRICAL CONNECTIONS
This ice dispenser requires an earth that meets the national and local electrical code requirements.
To prevent possible severe electrical shock to individuals or extensive damage to the unit, install a proper earth wire to the ice
dispenser.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 13A supply. The electrical supply must be protected by a suitable circuit
breaker.
* Usually an electrical permit and services of a licensed electrician are required.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured Green-and-Yellow must be connected to the terminal in the plug which is marked with the letter
E or by the symbol
terminal which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the
terminal which is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site not be suitable for the plug supplied with your product, the plug must be
removed (cut off if it is moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power supply cord, it must be disposed of. There should be no attempt to
reuse it. Inserting such a plug into a socket elsewhere presents a serious risk of electrical shock.
* The non-rewirable plug must never be used without a fuse cover being fitted.
The correct replacement for the detachable fuse cover is identifiable from the manufacturer's reference number stamped on
the plug.
Supply of replacement fuse covers can be obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS 1362.
7. WATER SUPPLY AND DRAIN CONNECTIONS
* The connections to the mains water supply must be made in accordance with the countries' current requirements of the Water
Supply or Water Fittings Regulations.
* To avoid performance reduction or malfunction caused by scaling, the water supply should have a hardness of not more
than 50 mg/L and a silica content of not more than 30 mg/L. Otherwise, installation of a proper water treatment device will be
required.
THIS APPLIANCE MUST BE EARTHED
or coloured Green or Green-and-Yellow. The wire which is coloured Blue must be connected to the
Connect to potable cold water supply only.
WARNING
WARNING
5
ENGLISH
Leg
Adjuster
Shorter
Longer