Caution!
Due to concentrated water content in the wet air outlet duct,
equipment. If the duct needs to be installed higher than the wet air outlet,
condensate drain does not create an icing hazard in winter.
Caution!
through the system."

1.8 ELECTRICAL INSTALLATION

Attention!
Wherever possible, all electrical work must be carried out with
conditioning plants.
Has completed the appropriate health and safety training.
Has read and is familiar with the contents of this manual.
If working on the unit's isolation switch, ensure that the plug is
unplugged from the electrical grid to prevent accidental resetting.
Electrical connection are to be made in accordance with local
regulations.
Attention!
Check incoming electrical voltage and operating frequency
conform to the electrical wiring diagram and the manufacturer's type plate
attached to the unit.
Caution!
Parameters used in the electrical protection and alarm circuits
in the electrical wiring diagrams, technical data or parameter list.
This equipment will contain high voltage electrical components!

1.9 OPERATION

Caution!
On no account should the unit be operated without air filters
installed!
Caution!
Do not expose the unit to ambient temperature that exceeds
50°C/122°F (e.g inside a plant room) for longer period of time. This may
damage the internal components!
Caution!
Do not process air with temperature higher than 40°C/104°F. This
may damage the internal components!
Caution!
through the system. The heat from the regeneration heater cannot be
conveyed to the wrong direction. Install preventive measures if necessary!

1.10 MAINTENANCE

Caution!
Defective electrical components and defective wiring must be
replaced immediately. The equipment must not be operated until the defect
has been repaired and the unit has been retested.
Attention!
Advise all operating & maintenance personnel regarding
automatic restart function if applicable.
Attention!
Pay attention to accessibility requirements for maintenance and
service purposes.
the unit's refrigerant system. Contact your DST representative for any
questions (Econosorb & Frigosorb only).
Caution!
The operation of all electric safety devices are to be checked at
commissioning and during service/maintenance. Under no circumstances
are these devices to be deactivated (e.g., adjustment or bridging).
Caution!
Do not rinse the unit with water.
Allow fans to come to a complete stop and the unit must be
isolated from the electrical supply before removing any panels!
Seibu Giken DST
The unit is equipped with a heating element. Do not touch the
equipment whilst it is hot. Allow the unit to cool for at least 15 minutes before
any service or maintenance is performed.

1.11 DISPOSAL/RECYCLING

When the unit is no longer in use and taking out of service - dismantle the unit and
recycle the components according to the local regulations. Contact your DST
representative for any questions.