Note!
If the verification of the positions should show that e.g. the actual positions 1 and 2 "run
past" the settings by approx. the same amount, then one can move the reference
position forward by this amount.
7.3.9 Setting Machine-specific Parameters with the V820 Control Panel
The machine-specific parameters can be set with the V820 control panel and are to be
found in the chapter 7.1.6 and in the parameter sheet (accessories pack).
The setting is described in Chapter 7.3.8.
7.3.10 Master Reset with the V820 Control Panel
All parameter values changed in relation to the preset values are reset to the preset
values by a master reset.
–
Turn the main switch off.
–
Press the "P" key, hold down and turn the main switch on.
–
Release th "P" key.
–
Enter the code number for the " Technician Level ". See Chapter 7.3.7
–
Press the "E" key. The parameter "F-100" is shown.
–
Press the "E" key. The value of the parameter "F-100" is shown.
–
Set the value to "170" .
–
Press the "P" key twice.
–
Turn the main switch off.
–
Turn the main switch on after a short wait. All parameters, except 1.1.1., 1.6.1.,
1.7.0., 1.7.1. and 1.9.0. to 1.9.3., have the preset values again.
46
* ATTENTION
The parameter values for the positions 1E, 2E, 1A and 2A
are to be found in the parameter sheet (accessories pack).
ATTENTION!
At a master reset several parameters such as e.g. F-170
(reference position), F-171 (needle position) and F-161
(motor direction of rotation) are not reset .
After a master reset all machine-specific parameters
must be set as per the parameter sheet again. See
Chapter 7.3.9