8.2.4 Changing Parameters at the Operator Level (A)
The parameter values at the operator level (see Parameter List 8.2.5) can be changed
as follows.
–
Turn the mains switch on, do not operate the pedal.
–
The "Manual Sewing" work mode is active (the LED in the key 5 (P/M)) is dark).
–
Press the 6 (T/E) key, the LED is lit, sewing is no longer possible.
–
The first parameter at the operator level is shown in the display.
Example:
NumberMeaning
1
Number of forward stitches in the beginning bartack
3
Number of reverse stitches in the beginning bartack
5
Number of reverse stitches in the end bartack
7
Number of forward stitches in the end bartack
10
Parameter number (hundreds)
11
Parameter number (tens)
12
Parameter number (ones)
14-16 Parameter value
–
The parameter value can be changed with the L+ or L- key
–
The parameter number can be changed with the P+ or P- key (hundreds) or with
the S+ or S- key (tens and ones).
–
Press the 6 (T/E) key, the setting is saved, the operator level A is exited, the LED is
dark and sewing is possible again.
8.2.5 Parameter List at the Operator Level (A)
Parameter
No.
Abbr.
Designation/Function
111
LS
Light barrier compensation stitches
112
LS
Number of stitches to the light barrier mark
by knitted goods
116
SANL
Number of softstart stitches
148
AR
Beginning bartack-double = I, single = II
149
ER
End bartack-double = I, single = II
450
LS/STL Light barrier compensation stitches by short
sewing length
523
RIE/
Change-over fancy-stitch bartack = I,
ZRIE
normal bartack = II
64
Change via:
P+ or P- key
S+ or S- key
S+ or S- key
L+ or L- key
Setting RangePreset
min
max
100R
1
255
6
0
255
0
0
255
2
I
II
I
I
II
I
1
255
6
I
II
II