8.1.7 Changing Parameters in the Operator Level (A) in the DA40MS02 Controls

Prerequisite: The mains switch is turned on, the pedal is in the base position, sewing is
not taking place, the display mode 4 is turned on (see Chapter 8.1.2)
Display
Display mode 4: Parameter and parameter value
Number
Meaning
1-3
Parameter
4
Programming level
5-8
Parameter value
Selecting parameters and changing the parameter value.
Press the C>> key, the number 1 in the display blinks, sewing is not longer
possible.
Press the V+ key, the value of the blinking number is increased or
Press the V- key, the value of the blinking number is decreased.
Press the C>> key, the numbers 2-3 in the display blink.
Press the V+ key, the value of the blinking number is increased or
Press the V- key, the value of the blinking number is decreased .
Repeat this procedure until the numbers 1-3 show the desired parameter value.
Press the C>> key, the numbers 5-8 in the display blink (parameter value).
Press the V+ key, the value of the blinking number is increased or
Press the V- key, the value of the blinking number is decreased .
Repeat this procedure until the numbers 5-8 show the desired parameter value.
Press the M+ or M- key, the blinking is ended, the change is thus saved, sewing is
possible again.
Change via:
V+ or V- key
-
V+ or V- key
GB