8.1.4 Reducing the Maximum Speed in the DA40MS02 controls
In order to optimally set the maximum speed of the machine to the current individual
application, a reduction of the maximum speed is possible.
Prerequisites:
–
The mains switch is turned on.
–
The pedal is in base position.
–
Sewing is not taking place.
–
The display mode 2 is turned on (see Chapter 8.1.2).
Display:
Display mode 2: Maximum speed
Number
Meaning
1
Character for the speed display
3-6
Stitches-rpm
8
Current programming level
Reducing the maximum speed
–
Press the V- key, the maximum speed is lowered
–
Press the V+ key, the maximum speed is increased
Note!
The setting range lies between the parameter value <607> (maximum) and <606>
(minimum).
52
ATTENTION!
The maximum speed (value of the parameter 607) should
be set no higher than is listed in the parameter sheet (in
the accessories pack) for each class and subclass..
Change via:
-
V+ or V- key
Chapter 8.1.7, 8.1.8, 8.1.9-