Firmware Update Procedure - Franklin Electric MONODRIVE UTILITY Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
Firmware Updates

Firmware Update Procedure

File Preparation
The latest firmware file can be downloaded from the Download tab of the SubDrive/MonoDrive page
on www.franklinwater.com.
NOTE: A good quality USB 2.0 compliant or newer device is required. Some older or lower-cost
devices may not be recognized by the drive.
Update Instructions
1. Remove power from the drive and allow 5 minutes for internal voltage to dissipate.
2. Remove the drive cover.
3. Insert the USB device into the USB port on the lower-left corner of the circuit board.
4. Reinstall the drive cover before applying power to the drive.
5. Apply power to the drive. The update procedure will begin automatically. The status of the
firmware update procedure is displayed using the display LEDs on the unit as follows:
Update Status
Step 1: USB Device Detected
Step 2: Copying files to drive
Step 3: Updating display board
Step 4: Updating power board
Step 5: Update complete
Update failed
6. When the update is complete, remove power from the drive and wait 5 minutes for internal
voltage to dissipate.
7. Remove the drive cover.
8. Remove the USB storage device.
9. Reinstall the drive cover.
10. Power on the drive. The drive is updated and will operate normally.
NOTE: If the update failed to complete, confirm the correct file is in the main directory of the USB
device and the filename was not changed. If the file location and name is correct, use a different
USB storage device and repeat this procedure.