Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TECHNICAL DESCRIPTION
CONNECTION
- Before making the electrical connections between the current generator and the line
switch, ensure that the switch is turned off .
- The distribution panel must comply with the regulations in force in the country of use
(
- The mains system must be of the industrial type.
- Provide a special socket which can receive the leads of the power cable (200A: 4mm
section ; 350A:6mm section ).
- For longer connecting cables, increase the lead section as required.
- Upstream, the mains socket must have a suitable switch provided with delayed fuses.
MODEL
HI-MIG 353S-P
HI-MIG 503S-P

3.4 - EARTHING

- To ensure user protection the welding machine must absolutely be correctly connect-
ed to the earth system (INTERNATIONAL SAFETY REGULATIONS).
- It is indispensable to provide good earthing by means of the yellow-green lead in the
power cable, in order to avoid discharges due to accidental contacts with earthed ob-
jects.
- The chassis (which is conductive) is electrically connected with the earth lead; if the
equipment is not suitably connected to earth it may cause electric shocks which are
dangerous for the user.
40
HI-MIG 353/503S-P 400V 3F
).
VOLTAGE/PHASES
400V 3 phases without neutral
400V 3 phases without neutral
COD. 6907900030
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
ENGLISH
DELAYED FUSE
50 A
50 A
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6907900030