2
CORRECT USE
3
Commissioning
2
Image: A
1
Adjust the distance between the sensor and the reflector according to the corre‐
sponding diagram [H] (x = sensing range, y = operating reserve).
Image: H
2
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of 0.56 Nm.
3
The sensors must be connected in a voltage-free state (U
in the graphics [B] must be observed, depending on the connection type:
–
Male connector connection: pin assignment
–
Cable: core color
1
brn
+ (L+)
4
blk
Q
1
2
wht
Q
2
3
blu
- (M)
Image: B
Image: B-2
-x4xxxx /
-x1xxxx
-x3xxxx
1
brn
brn
+ (L+)
3
wht
blu
Q
2
4
blu
blk
- (M)
blk
Q
1
Image: B-3
--x2xxxx
= 0 V). The information
v
+ (L+)
- (M)
Q
8017856.YMH6 | SICK Subject
to change without notice