12.1- ENCLOSURE PARTS
The enclosure is made up of a main structure (floor of the cabin, the structural beams and the instrumentation panel), fixed
panels (side panels and roof) and panels that can be disassembled (front and rear panel).
The front panel is designed to allow maintenance access, there are two folding doors to access for the belt tightening, inlet
filter maintenance and oil level checks (also available from outside). Enclosure doors are opened by a key delivered with
the enclosure. In order to start the blower, all the doors must be locked and the panels assembled. (IMPORTANT: Don't
start the blower if any panel is disassembled or door opened.)
All the panels of the enclosure are equipped with two pressure latches to make easy the handling. The rear panel is
removeable to allow access for maintenance of the valves (pressure or vacuum unloading valve, unloading valve and
non-return valve), and in big sizes (from DN-200 to DN-300) to the rear tension screw of the frame.
12.2- DETAIL OF HOW THE BOLTS ARE POSITIONED IN THE ENCLOSURE BASE
VENTILATION
FAN
FRAME
PACKAGE
UNIT
FIXINGS
BASE FIXING
PLATES
ENCLOSURE BASE
RETAINING BOLT
FRONT ACCESS DOORS
WASHER
DROP-IN ANCHORS