Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
PUPILLA/PUPILLA.T
DESCRIPTION
Pair of photocells for wall installation with 24 Vac/
dc power supply.
The PUPILLA version can be orientated 180° and
allows synchronisation of up to 4 pairs.
The PUPILLA.T version avails of an internal card
orientated over three positions: front, right and left,
PUPILLA.T does not allow synchronisation.
INSTALLATION
Photocell opening
Use a screwdriver for leverage on the lower central
part as indicated in Fig.1.
Photocell base fastening (Fig.2)
Fasten the base of photocell A using the screws and
plugs suitable for the type of fastening surface.
There are two steps for connection cable passage:
one on the base (G) and one on the cover (H)
Centring adjustment (PUPILLA only)
Adjustment of photocell centring is carried out by
loosening the screws E (Fig. 3).
The card can rotate 180°.
Card fastening (PUPILLA.T only)
You can insert the card of the receiver/transmitter on
three different positions (Fig.4):
Front (A) - Right (B) - Left (B)
Having chosen the suitable position, fasten the card
with screw V
PUPILLA connection (Fig.5)
TX
M1: 24Vac (+24Vdc)
M2: 24Vac (-24Vdc)
RX
M1: 24Vac (+24Vdc)
M2: 24Vac (-24Vdc)
M3: Common, COM.
M4: Normally open contact, N.O.
M5: Normally closed contact, N.C.*
*With photocell powered and aligned.

TECHNICAL DATA

Power supply
Capacity
Working temperature
Absorption*
Protection rating
Size
* With photocell powered, aligned and Phototest logic OFF.
8
PUPILLA
22÷30 Vac - 20÷28Vdc 50/60 Hz
TX: 40 mA (Vdc) - 75 mA (Vac)
RX: 20 mA (Vdc) - 40 mA (Vac)
PUPILLA.T connection (Fig.6)
TX
M1: 24Vac (+24Vdc)
M2: 24Vac (-24Vdc)
RX
M1: 24Vac (+24Vdc)
M2: 24Vac (-24Vdc)
M3: Common, COM.
M4: Normally closed contact, N.C.*
*With photocell powered and aligned.
Alignment check
Once the photocells are powered, the LED flashing on
the RX receiver indicates the reception level:
Slow flashing LED: weak reception
Fast flashing LED: good reception
LED on: excellent reception.
If reception is not excellent, correct orientation of
the photocells.
Synchronism (PUPILLA only)
To avoid interference in the event of use of the two
pairs of close photocells, activate synchronism by
removing the metal gear NT2, highlighted in Figure
5, with a screwdriver or drill bit.
Synchronism works exclusively with 22÷30 Vac
power supply with polarity inverted between the two
pairs as indicated in Fig. 7/8.
IMPORTANT: To prevent infiltration of humidity
and condensate phenomena, seal with utmost
care, using a silicone product. Seal both the cable
in the duct and the fastening base at the entrance
hole of the duct.
14÷30 Vac - 12÷30 Vdc 50/60 Hz
20-25 m
-20°C / +70°C
TX: 20 mA (Vdc) - 40 mA (Vac)
RX: 20 mA (Vdc) - 40 mA (Vac)
IP44
110x35x35 (mm)
PUPILLA.T

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pupilla.t

Tabla de contenido