A representation of the grid appears on the screen with
a suggested starting point (triangle). This is always at
upper left and will be suitable for most scans. Image
data will be generated only for areas of the grid that have
been scanned both vertically and horizontally. In some
cases, obstacles in the scan area may prevent this (e.g.
a pipe penetrating a beam). The starting point may be
changed in such cases in order to allow the area to be
scanned optimally. Use the Arrow buttons to change the
starting point.
Place the scanner on the grid at the starting point shown
by the flashing arrow. Ensure the alignment marks on
the scanner are aligned correctly with the reference grid
as shown above.
Note
Incorrect alignment of the scanner on the refer-
ence grid may lead to the bar positions being in-
correct in the image generated.
Press Record and move the scanner along the first row.
Scanning progress is indicated by a thick black line that
advances across the display as the scanner is moved
over the surface.
The scanner emits a double beep at the end of the row and automatically stops recording. This procedure
should be repeated for each row and column while observing the instructions shown in the display.