Malfunction
The scanner doesn't record
while making an Imagescan.
The scanner doesn't record.
The data is not transferred
between the scanner and the
tablet.
The data is not transferred
between the scanner and the
tablet.
The data is not transferred
between the scanner and the
PSA 55 adapter.
46
English
Printed: 14.11.2016 | Doc-Nr: PUB / 5314765 / 000 / 00
Possible cause
The maximum scanning speed of
0.5 m/s was exceeded.
This symbol may appear if the
scanner is moved in the wrong di-
rection when in Quickscan record-
ing mode, i.e. you begin scanning,
for example, from right to left but at
some point during the Quickscan
recording you move the scanner to
the right.
Data transfer was interrupted or
a connection could not be estab-
lished.
Indicates that the scanner or tablet
may be defective.
Indicates that the scanner or
adapter may be defective.
Action to be taken
▶ Press the Confirm button. Scan
the row or column again. Move
the scanner over the surface
more slowly.
▶ Press the Confirm button and
repeat the scan. Move the
scanner in the correct direction.
▶ NOTE The warning does not
appear immediately, but only
when the scanner is moved
15 cm or more in the wrong
direction.
▶ Check that the scanner and
tablet are positioned within
maximum range (30 cm) and
that they are correctly aligned
with each other.
▶ Check that the PSA 56 infrared
adapter is plugged in correctly.
▶ Make sure that the atmosphere
is as dust-free as possible and
that the infrared windows on
both scanner and tablet are
clean and not badly scratched.
Badly scratched infrared win-
dows must be replaced by Hilti
Service.
▶ Try to hold the tablet and
scanner steady and in correct
alignment with each other until
data transfer is completed.
▶ Try to hold the tablet and
scanner steady and in correct
alignment with each other until
data transfer is completed.
▶ Remedy the problem by switch-
ing the units off and on or
adjusting their alignment with
each other.
▶ NOTE Data will not be lost
in the event of an interruption
during data transfer. Data is
deleted from the scanner only
once all scan data has been
correctly transferred and the
Confirm button on the scanner
is pressed. If the error message
reappears, the appliance will
need to be sent to Hilti for
repair.
▶ Remedy the problem by switch-
ing the unit off and on or
adjusting its alignment.