All scan data has then been successfully transferred.
Press the Confirm button on the scanner again to end
the data transfer procedure. The scan data has been
successfully transferred.
The scans are numbered by the adapter.
5.16.3 Transferring data from the adapter to the computer
Note
To ensure data security, data integrity and to avoid malfunctions, use only the PUA 95 Micro USB
cable supplied by Hilti.
The PUA 95 Micro USB data cable is used to transfer data from the adapter to the computer. The adapter
can be removed once data transfer is complete.
Note
In order to remove the PSA 55 adapter safely, we recommend use of the "Remove hardware safely"
function of the operating system. This helps prevent loss of data integrity.
5.16.4 Transferring data from the tablet to the computer
Note
To ensure data security, data integrity and to avoid malfunctions, use only the PSA 92 Micro USB
cable supplied by Hilti.
The PSA 92 USB data cable is used to transfer data from the tablet to the computer.
5.16.5 Tips for scanning and evaluation
The object is too narrow to scan or reinforcement is too close to an outside edge to be scanned properly
Use a thin sheet of non-metallic material (e.g cardboard,
wood, polystyrene foam, etc.) as an overlay that extends
beyond the edge. The scanner can then be moved over
the sheet to beyond the edge of the structure. Note that
the thickness of the overlay sheet must be deducted
from any depth measurements. The thickness of the
overlay sheet can be entered in the PC application. This
value will then be automatically deducted from any depth
measurements.
The surface is rough.
Rough surfaces (e.g. concrete surfaces with exposed
aggregates) cause additional noise in the signal and may
mean that the depth or diameter of a bar cannot be
determined. In such cases it is also advantageous to
scan through a thin overlay sheet. Also in this case, the
thickness of the overlay sheet must be deducted from
any depth measurements.
"Interference" in images
44
English
Printed: 14.11.2016 | Doc-Nr: PUB / 5314765 / 000 / 00