Malfunction
The data is not transferred
between the scanner and the
PSA 56 adapter.
This symbol indicates a crit-
ical error in the scanner and
may appear immediately after
switching on.
This symbol indicates a crit-
ical error in the scanner and
may appear immediately after
switching on.
This symbol indicates an op-
erator error and may appear
when starting various scan-
ning activities.
6.2 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
The scanner doesn't start.
The scanner doesn't run
freely.
The scanner may be operated
only for a short time before
the battery is exhausted.
The scan date and time are
not correct.
Printed: 14.11.2016 | Doc-Nr: PUB / 5314765 / 000 / 00
Possible cause
Indicates that the scanner or
adapter may be defective.
They indicate a possible electronic
fault.
They indicate a possible electronic
fault.
This indicates that the memory al-
located to the operation is full and
that no more data can be stored.
Possible cause
The battery is not charged.
The contacts on the battery or in
the scanner are dirty.
The battery is old or defective, or
the maximum number of charging
cycles has been exceeded.
The wheels are dirty or dusty.
The drive belt or gear teeth are
worn.
The battery is old or defective, or
the maximum number of charging
cycles has been exceeded.
The date has not yet been set with
the Hilti PROFIS Detection PC
application.
Action to be taken
▶ Remedy the problem by switch-
ing the unit off and on or
adjusting its alignment.
▶ Switch the scanner off and then
back on again. If the error
message appears again, the
appliance will need to be sent
to Hilti for repair.
▶ Switch the scanner off and then
back on again. If the error
message appears again, the
appliance will need to be sent
to Hilti for repair.
▶ In this situation, the data must
either be transferred to the
tablet or deleted from scanner
memory.
▶ CAUTION Deleting the contents
of scanner memory may result
in data loss. Data that has
not been transferred to the
tablet before deletion will be
permanently lost.
Action to be taken
▶ Change the battery.
▶ Clean the contacts.
▶ Contact Hilti Service.
▶ Remove the wheels and casing
and clean the parts.
▶ Contact Hilti Service.
▶ Contact Hilti Service.
▶ Install Hilti PROFIS Detection
and start the application.
▶ Connect the PSA 55 IR with the
data cable and set the date and
time.