Protective de-
Charger switches off during charging
vices tripping
Cause:
(continued)
Remedy:
Charging errors
Operating indicator on, fault indicator flashing, charge level indicator 3/4 flashing
Cause:
Cause:
Remedy:
Operating indicator on, fault indicator flashing, charge level indicator 1/2/3/4
flashing
Cause:
Remedy:
Cause:
Remedy:
All manuals and user guides at all-guides.com
Ambient temperature too high. Overtemperature protection active
Allow charger to cool down. Charging will recommence automatically once
the charger has cooled sufficiently. If not, have it checked by a workshop.
Timeout in the corresponding charging phase, or battery capacity too high
Battery faulty (cell short circuit, heavy sulphation)
Check battery and replace if necessary
Optional external temperature sensor has tripped due to over or undertem-
perature
Allow battery to cool, or charge battery in a more suitable area
Battery faulty (cell short circuit, heavy sulphation)
Check battery and replace if necessary
11