1
Safety notes
2
Correct use
3
Commissioning
8017858.YMH6 | SICK
Subject to change without notice
Photoelectric proximity sensor
Operating instructions
Read the operating instructions before commissioning.
■
Connection, mounting, and setting may only be performed by trained specialists.
■
Not a safety component in accordance with the EU Machinery Directive.
■
When commissioning, protect the device from moisture and contamination.
■
These operating instructions contain information required during the life cycle of
■
the sensor.
The HTF18 is an opto-electronic photoelectric proximity sensor (referred to as "sensor"
in the following) for the optical, non-contact detection of objects, animals, and persons.
If the product is used for any other purpose or modified in any way, any warranty claim
against SICK AG shall become void.
Photoelectric proximity sensor with foreground suppression.
Image: A
1
Check the application conditions: Adjust the sensing range and distance to the ob‐
ject or background and the remission capability of the object according to the cor‐
responding diagram [H] (x = sensing range, y = transition range between the set
sensing range (background) and the object as a % of the sensing range (object re‐
mission / background remission)). Remission: 6% = black , 18% = grey , 90%
= white (referring to standard white as per DIN 5033).
The minimum distance (= y) for reliable object detection can be determined from
diagram [H] as follows:
1