DC Current
Range
4 mA ~ 400 mA
10A
AC Current (40 Hz ~ 1 kHz)
4 mA ~ 400 mA
10A
Ranges: 4 mA, 40 mA, 400 mA, 10A
Resolution: 1 µA in the 4 mA range
AC Conversion Type: AC-coupled, true RMS responding, calibrated to the RMS value
sine wave input. The specified accuracy is for sine wave at full scale and non-sine wave
at half scale below 500 Hz with crest factor up to 2.
All manuals and user guides at all-guides.com
Accuracy
± (0.4% + 2 digits)
± (0.8% + 4 digits)
± (1 % + 5 digits)
± (1 % + 5 digits)
Burden Voltage
800 mV max.
1 V max.
800 mV max.
1 V max.
93-105 / 00408
Input Protection
1A / 600V fuse
15A / 600V fuse
1A / 600V fuse
15A / 600V fuse
17