Site Preparation
Electrical Requirements
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit servicing only this appliance is required.
IMPORTANT NOTE: For indoor models, a ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
For the outdoor model, a ground fault circuit interrupter
(GFCI) is required to reduce the risk of electrical shock.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL SUPPLY LOCATION
18" Model
24" Model
27" Model
30" Model
36" Model
LEFT SIDE
OF OPENING
1
4
/
"
A
2
(114)
4
1
/
"
4
(108)
FLOOR
1
1
/
/
"
"
4
4
(6)
(6)
Electrical supply location
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
WARNING
Do not use an extension cord, two-prong adapter, or
A
remove the power cord ground prong.
6"
(152)
9 1/2"
(241)
ELECTRICAL REQUIREMENTS
11"
(279)
Electrical Supply
12 1/2"
(318)
Service
15 1/2"
(394)
Receptacle
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
subzero.com | 5