BUILT-IN INSTALLATION INSTRUCTIONS

ELECTRICAL REQUIREMENTS

A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker
and electrical supply are required. A separate
circuit, servicing only this appliance, is required.
All Sub-Zero Built-In models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding-type wall receptacle. Follow
local codes and ordinances when installing the
receptacle. For location of the electrical supply,
refer to the Installation Specifications illustration
for your specific model on pages 4–6.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
WARNING
Do not use an extension cord or two-prong
adapter. Electrical ground is required on this
appliance. Do not remove the power supply
cord ground prong.
CAUTION
The outlet must be checked by a qualified
electrician to be sure that it is wired with the
correct polarity. Verify that the outlet
provides 220-240 V AC and is properly
grounded.
WARNING
Always shut power off at the circuit breaker
before performing any installation, service or
maintenance.
All manuals and user guides at all-guides.com
IMPORTANT NOTE: The Built-In line is
equipped with an appliance inlet type device.
This allows easy replacement of the power
cord. The appliance inlet is located on top of
the unit on the compressor shroud. When
replacing the power cord make sure that the
replacement cord is rated HO5VV-F3G1.0 or
equivalent to ensure safe operation of the
appliance.

PLUMBING REQUIREMENTS

IMPORTANT NOTE: A reverse osmosis system
can be used, provided there is constant water
pressure of 2.1 bar to 6.9 bar supplied to the unit
at all times.
Rough in the cold water supply line using 6 mm
OD copper line. The water line should be routed
up through the floor within 13 mm from the back
wall and no higher than 76 mm off the floor. If
you have to come through the wall, make sure
the water line is no more than 76 mm from the
floor.
Regardless of the routing, allow .9 m of excess
copper tubing to remain outside the wall or floor
for easy connection to the unit. Locate the water
supply line within the shaded area indicated in
the Installation Specifications illustration for
your specific model on pages 4–6.
Use an easily accessible shut-off valve between
the water supply and the unit. Do not use
self-piercing valves. A saddle valve kit (4200880)
is available from your Sub-Zero dealer.
It is not recommended that the ice maker be
connected to a softened water supply. Water
softener chemicals, such as salt from a malfunc-
tioning softener, can damage the ice maker and
lead to poor ice quality. If a softened water
supply cannot be avoided, be sure that the water
softener is well maintained and operating
properly.
IMPORTANT NOTE: All installations must meet
local plumbing code requirements.
IMPORTANT NOTE: This appliance should be
connected to a potable water supply.

UNPACK THE UNIT

Uncrate the unit and inspect for any damages.
Remove the wood base and discard the shipping
bolts and brackets that hold the wood base to
the bottom of the unit. Remove and discard all
packing materials.
IMPORTANT NOTE: Do not discard the kick-
plate, anti-tip bracket and hardware. These items
will be needed for installation.
Retract the front leveling legs all the way up to
allow the unit to be moved into position more
easily. You will extend the leveling legs when the
unit is in its final position to reduce the possibil-
ity of the unit tipping forward.
IMPORTANT NOTE: The rear levelers must be in
their lowest position in order to push the unit
back into the rough opening. Therefore, leveling
cannot be completed until the unit is in position.
Remove the drain pan from the base of the unit
to avoid damage to the drain pan, and allow for
proper placement of the appliance dolly.
WARNING
Be sure to secure the door(s) closed before
moving the unit.