Technical data

POWER SOURCE
Mains voltage ±15% (50-60Hz), V
Minimum generator size, kVA
Fuse, A
Mains current, effective, A
Mains current, max., A
Power, 100%, kVA
Power, max., kVA
Power, open circuit, VA
Efficiency, %
Power factor
Current range, A
Duty cycle, 100% 20°C (MIG), A/V
Duty cycle, max. 20°C (MIG), A/%/V
Duty cycle, 100% 40°C (MIG), A/V
Duty cycle, 60% 40°C (MIG), A/V
Duty cycle, max. 40°C (MIG), A/%/V
Open circuit voltage, V
1)
Sphere of application
Protection class
2)
Standards
Dimensions (HxWxL), mm
Weight, kg
COOLING UNIT
Cooling capacity (1.0 l/min), W
Cooling capacity (1.5 l/min), W
Tank capacity, liter
Flow, bar - °C - l/min
Pressure max., bar
Standards
1) This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks.
2) The machine is designed for indoor and outdoor use according to protection class IP23S. The machine may be stored but is not intended to be used outside during
precipitation unless sheltered.
SIGMA ROBO
3x400
36
32
29.3 (380V)/27.8 (400V)
36.8 (380V)/35.0 (400V)
17.9
24.2
40
90
0.90
15-500
475/37.8
500/80/39.0
420/35.0
450/36.5
500/55/39.0
78-95
S/CE/CCC
IP23S
EN/IEC60974-1.
EN/IEC60974-2.
EN/IEC60974-10
1092 x 614 x 410
71
1650
1900
3.5
3.0 - 60 - 1.5
4.5
EN/IEC60974-2
17
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: SIGMA ROBO
conforms to directives: 2014/35/EU
2014/30/EU
2011/65/EU
European standards:
EN IEC60974-1:2018/A1:2019
EN IEC60974-2:2019
EN / IEC60974-10:2014/A1:2015
Regulation:
2019/1784/EU
Issued in Fjerritslev 10.02.2021
Kristian M. Madsen
CEO