The LED Light on the Charger
Power On (Green light flashes slowly)
Battery Low (Red light stays illuminated)
Battery charged 80% (Green light flashes rapidly)
Battery charged 100% (Green light stays illuminated)
Battery Pack temperature is too hot or too cold (Red light flashes slowly)
Battery Pack malfunction (Red and Green lights stay illuminated)
or
WARNING!
1. Charger is plugged into a 100-240V a.e outlet only.
2. lf the battery pack is too hot or too cold, the charger will not fast charge the battery pack and
the red lndicator light is "blinking". When the battery pack temperature returns to between
0ºC(32ºF) and 50ºC(122ºF), The charger will automatically begin charging.
3. lf both red and green indicator lights are "ON" the battery pack either does not comply or is
detective. Please contact your retailer.
4. Do not charge the battery pack in the rain, snow or high temperature environment.
5. Do not charge battery pack when environment temperature is below 0ºC (32ºF)or above
40ºC (104ºF)
6. While charge the cool battery pack (below 0ºC) in the warm indoor, keep the battery pack in
the room far one hour to warm up befare starting the battery pack.
A cool battery may charge unsaturated.
7. Remove the plug after finishing the charge.
8. The charger should be cooled at least one hour after continue charging three times.
9. Do not use generator far charging the battery pack.