GENERAL INFORMATION
COMPONENT IDENTIFICATION –
ENGINE
2
1
1.
Engine Starter
2.
Engine Oil Dipstick
3.
Spark Plug
16
Part No. 101048 Rev. B
All manuals and user guides at all-guides.com
3
5
Figure 2
4.
Fuel Mixture Valve
5.
Air Cleaner
CONTROL PANEL
MAIN CIRCUIT BREAKER
The 35.5-amp main circuit breaker protects the generator from
circuit overload. The main circuit breaker controls total output of
the generator. (Figure 3)
4
INTERRUPTOR DE CIRCUITO PRINCIPAL
ON
MARCHE
ENCENDIDO
EXERCISE SWITCH
The exercise switch incorporates a built-in timer. The generator
will automatically perform an exercise period once every
seven days (168 hours). At the start of the exercise period, the
engine will start and run for 15 minutes. Load transfer from the
generator output will not occur unless the utility power is lost.
When the switch is in the OFF position, the exercise function is
disabled. Refer to Set Exercise Time to reset. (Figure 4)
EXERCISE / EXERCICE
MAIN CIRCUIT BREAKER
DISJONCTEUR PRINCIPAL
Figure 3
EJERCICIO
ON
MARCHE
ENCENDIDO
OFF
ARRÊT
APAGADO
Figure 4