Grounding Instructions - Titan AirCoat 0508074A Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Important Safety Information
haZaRD:
GENERaL
Can cause severe injury or property damage.
PREvENTION:
Read all instructions and safety precautions before operating
equipment.
Follow all appropriate local, state, and national codes governing
ventilation, fire prevention, and operation.
The United States Government Safety Standards have been
adopted under the Occupational Safety and Health Act (OSHA).
These standards, particularly part 1910 of the General Standards
and part 1926 of the Construction Standards should be consulted.
Use only manufacturer authorized parts. User assumes all risks
and liabilities when using parts that do not meet the minimum
specifications and safety requirements of the pump manufacturer.
All hoses, fittings, and filter parts must be secured before
operating spray pump. Unsecured parts can eject at great force
or leak a high pressure fluid stream causing severe injury.
Before each use, check all hoses for cuts, leaks, abrasion or
bulging of cover. Check for damage or movement of couplings.
Immediately replace the hose if any of these conditions exist.
Never repair a paint hose. Replace it with another grounded high-
pressure hose.
Do not kink or over-bend the hose. Airless hose can develop
leaks from wear, kinking and abuse. A leak can inject material
into the skin.
Do not expose the hose to temperatures or pressures in excess of
those specified by manufacturer.
Do not spray outdoors on windy days.
Wear clothing to keep paint off skin and hair.
Do not operate or spray near children. Keep children away from
the equipment at all times.
Do not overreach or stand on an unstable support. Keep effective
footing and balance at all times.
Use lowest possible pressure to flush equipment.
Stay alert and watch what you are doing.
Do not operate the unit when fatigued or under the influence of
drugs or alcohol.
For electric units — Always unplug cord from outlet before
working on equipment.
Do not use the hose as a strength member to pull or lift the
equipment.
Do not lift by cart handle when loading or unloading.
haZaRD:
GaS ENGINE (WhERE aPPLIcaBLE)
Always place unit outside of structure in fresh air. Keep
all solvents away from engine exhaust. Never fill fuel tank
with a running or hot engine. Hot surface can ignite spilled
fuel. Always attach ground wire from pump to a grounded
object. Refer to engine owner's manual for complete safety
information.
IMPORTaNT: The diaphragm pump is provided with
a thermally protected automatic reset. If an overload occurs the
thermally protected automatic reset disconnects the motor from the
power supply.
The motor will restart without warning when the protector
automatically resets.
Always disconnect the motor from the power supply before
working on the equipment.
When the thermally protected automatic reset disconnects the
motor from the power supply, relieve pressure by turning the
PRIME/SPRAY valve to PRIME.
Turn the pump ON/OFF switch to OFF.
NOTE:
The cause of the overload should be corrected before
restarting. Refer to the Troubleshooting section.
© Titan Tool. All rights reserved.
operating the equipment. SavE ThESE INSTRucTIONS.
·
Read all safety information before

Grounding Instructions

This product must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape
wire for the electric current. This product is equipped with a cord having
a grounding wire with an appropriate grounding plug. The plug must
be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WaRNING - Improper installation of the grounding plug
can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary,
do not connect the green grounding wire to either flat blade
terminal. The wire with insulation having a green outer
surface with or without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the grounding
instructions are not completely understood, or if you are in doubt as
to whether the product is properly grounded. Do not modify the plug
provided. If the plug will not fit the outlet, have the proper outlet installed
by a qualified electrician.
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
IMPORTaNT: use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept the plug on
the product. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough
to carry the current your product will draw. an undersized cord
will cause a drop in line voltage resulting in loss of power and
overheating. a 12 gauge cord is recommended. If an extension
cord is to be used outdoors, it must be marked with the suffix
W-a after the cord type designation. For example, a designation
of SjTW-a would indicate that the cord would be appropriate for
outdoor use.
Minimum gauge for extension cords
Voltage
Ampere
rating
120V
range
12 - 14
NOTE:
More than 100 feet of extension cord is not
recommended. use more paint hose, not more
extension cord. Shorter extension cords will assure
maximum electrical power for proper operation.
3
Cord length (feet)
25
50
100
16
12
10
English