The protection class is determined by the requirements, which may be of a mechanical, chemi-
cal or thermal nature or due to similar influences that do not call for a Category 2 protection
class. A risk analysis must be carried out through a wearer trial if the required size is to be speci-
fied so that the glove fits. It should be noted that the function might be negatively affected when
using accessories, such as under-gloves.
The gloves must be properly stored, i.e. in boxes in dry spaces. Effects such as humidity, tem-
perature, light and natural changes in materials over time may lead to changes in the character-
istics. A shelf life cannot be specified, because that will depend on the degree of wear, and the
type of use and the working sites.
We recommend that you clean it using commercially available cleaning utensils (e.g. brushes,
polishing cloths, etc.). Washing or chemical cleaning requires prior consultation with an author-
ised specialist company.
The manufacturer can accept no liability for changes in the characteristics. Always ensure that
the gloves are intact before you use them.
5.9
Commissioning
The pipe cleaning machine should solely be operated by instructed and au-
thorised personnel!
Check the electrical installation at the work place!
Slide the battery into the housing and check that it is securely seated.
5.10
Operation
The pipe cleaning machine is only to be used after taking into account all of
the notices concerning safety of people and the machine!
Check to ensure that the protective tube is attached to the machine.
Attach the protective tube first and then slide in a suitable spiral and attach a suitable tool.
Position the machine so that it is about 50 cm away from the opening in the pipe that has to
be cleaned. Use the button to switch the controller to ready for operation and set it to clock-
wise rotation.
Use the +/- buttons to set the speed level. Select the speed level according to the working
process (unblocking, cleaning, spin-cleaning). The LEDs on the control panel will light up
according to your selection.
Feed the spiral in so that it is about 50 cm into the pipe. Now press the clamping lever so
that the spiral rotates.
Wear the enclosed special protective gloves to guide the spiral in and always wear
protective goggles when working!
Release the clamping lever and then slide the spiral further into the pipe. Repeat the proce-
dure until you can feel counter-pressure; you have reached the blockage!
Pull the spiral out of the machine until it is pre-tensioned into a working arc.
Do not let the working arc become too big - risk of injuries!
Press the clamping lever and then move the spiral's working arc up against the blockage.
If the spiral has penetrated the pipe so far that the working arc starts to collapse, release the
clamping lever, pull the spiral out of the machine and make a new working arc.
Repeat the process by pulling it back and forth until the blockage has been cleared, then re-
lease the clamping lever and pull the spiral out.
If it is difficult to move, press the clamping lever and allow the spiral to rotate briefly.
If it is difficult to move, you must ensure that rotating right / left stops the spiral from jamming
through starting (right) and releasing (left).