PROBLEM
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
9. CE INFORMATION
The CE label is located on the appliance. This label contains technical data and OF number. (This number can also
be found in the guarantee). THIS NUMBER IS ESSENTIALFOR ORDERING SPARE PARTS.
The review of the appliance, the installation and ducts must be carried out by a professional.
In case of doubt regarding the described herein, please contact your Rocal dealer.
WARNING:
-
All tests are carried out in observance of Regulationsm UNE-EN 13229:2002 - UNE-EN 13229:2002/A2:2005 -
UNE-EN 13229:2002/AC:2006– UNE-EN 3229:2002/A2:2005/AC:2007 - UNE-EN 60335
-
The review of the equipment, the installation and ducts must be carried out by a professional.
-
In case of doubt regarding the described herein, please contact your Rocal dealer.
-
FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER HANDLING OF THE
EQUIPMENT SHALL EXONERATE THE MANUFACTURER OF ANY LIABILITY.
CAUSE
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Incorrect duct
Combustion control registers in the wrong position
SOLUTION
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
14