on the door. When the apparatus is hot enough close the door, adjust the primary register to avoid excessive combustion and control
the intensity of fire by the secondary register.
IMPORTANT:
-The interior vermiculite parts SHOULD NOT RECEIVE IMPACTS when refueling is performed.
If any of these parts crack, but is properly set in its place, THE PROPER OPERATION OF THE
APPLIANCE SHALL NOT BE ALTERED AND THERE IS NO POTENTIAL RISK. The equipment can be
used normally. These cracks do not entail any manufacturing defect so they do not fall under guarantee
4.6 Loading and reloading of fuel. The loading should be taken once the flame is going out and only remains embers. Do not
exceed the maximum allowed load or reload. (See Table of Technical specifications).
4.7 Door opening. The door must be opened only for reloading. The door must be opened slowly to prevent smoke leakage. To open
it, follow the steps described in picture "C.1" of the ANNEXED document.
4.8 Operation in adverse weather conditions. It is possible for the device to malfunction due to sudden or unexpected weather
changes, causing: low pressure, ebb currents of air into the smoke duct. When these phenomena are observed it is advisable to close
the combustion register and turn the equipment off.
4.9 Fire Prevention. You must not place any flammable element outside the safety distance from the fireplace described in the table
in section 1.1 Technical specifications. You shall also take special precautions if there are children and elderly people present. In
case of fire, push away all the people around it, close the registers as much as possible and notify the Firefighting service.
4.10 Dilations of the sheet. Materials subject to temperature changes undergo dilatations. This phenomenon can cause sporadic
metallic noises more or less frequently. These are completely innocuous and do not mean any risk or problem for its operation.
5. ELECTRICAL INSTALLATION
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE NATIONAL OREUROPEAN NORMS
MUST BE ACCOMPLISHED WHEN PROCEEDING TO CONNECT THEA PPARATUS TO ELECTRICAL
INSTALLATIONS
5.1. Components. The appliance is equipped with two fans for models RCr 70, RCr 70A, and with four fans RCr 80, RCr 100, a
thermostat and an ignition device, resistance, turbine control switch, inner cables and wires as well as silicon tube for air outlet. For
parts refer to part V of the ANNEXED document.
5.2.1 Electrical diagram with 2 fans.
5.2.2 Electrical diagram with 4 fans.
5.3. Operating. The function of the vent set is to jet the air, once heated, from the lower grill of the apparatus to the front part and the
pipes in the upper part.
5.4. Use and maintenance. The set of ventilation should be permanently connected to the grid when the device is switched on.
The switch offers three positions:
Position 0: Automatic slow gear. The starting and stoppage of the turbines is through the automatic thermostat
-
Position I: Automatic fast gear. The starting and stoppage of the turbines is through the automatic thermostat
-
Position II: Manual fast gear. Manual, not automatic shutdown system.
-
After a period of prolonged and stop before putting the machine in motion, it is necessary to verify the proper operation of the turbines
and cleaned all the dirt of the front grilles of the air intake. It is also desirable that a qualified professional review the entire electrical
installation of the device.
WARNING:
If the feeding wires are damaged, they must be replaced either by sales department or qualified staff to avoid problems.
If an external speed controller is used, switch position I must be selected
6. CLEANING AND MAINTENANCE
6.1 Maintenance. An appropriate and regular maintenance of both the appliance and the installation contributes greatly to its good
performance. It is important to perform periodic and complete controls of the equipment, ceramic rope joints, the ducts and installation.
Thus, for your safety and comfort, some of our dealers offer a servicing contract for your device. Please contact your dealer
for this service.
.