Rothenberger SUPERTRONIC 2000 Instrucciones De Uso página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
5. To insert the head into the adapter, move the mobile part of the latter counter-clockwise until it is
completely inserted. This will spring back securing the head. To remove it, proceed in likewise manner.
6. Next insert the machine in the tube and make sure that it is securely guided into its housing by the tube
clamp bolt.
7. Check that the reverse gear lever is correctly in place (arrow in working direction). Press the electric switch
with your right hand. Rotation will start immediately. Now the head should be moved towards the tube
to start the threading process by pressing on the machine.
8. As soon as threading has begun, the head should be constantly and abundantly lubricated with threading
oil ROTHENBERGER.
9. Once the appropiate threading length has been achieved (the tube of the threading head should
never overhang in a normal thread), stop the motor. Change the position of the reverse gear lever
and start the motor. The machine will begin to unscrew the head and the tube will become free.
ATTENTION! Fast speed must only be used to unscrew the head. Never thread on fast speed.
7.
Diagnosis of faults
Before carrying out any job on the machine, disconnect the plug from the mains outlet.
ATTENTION! If any additional service is needed other than those indicated below, please contact the
nearest technical service station.
Insufficient power
Off-centre threading
Insufficient thread lenght
Poor thread quality.
Incorrect adjustment of threa-
ding head
Locked Shift lever
- Make sure that extension cable is not too long or that it does
not have insufficient section.
- Make sure that the right working speed is being used.
- Tube clamp must be well secured (bolt parallel to tube).
- Check operating condition of threading heads.
- Apply plenty and continuous lubrication to threading heads.
- Make sure that the tube can be screwed.
- Check position of tube fastener (shaft parallel to tube).
- Check condition and quality of tube.
- Check correct positioning of tube fastener.
- Make sure that there is no obstruction between the machine
and the tube fastener.
- Check condition of teeth.
- Check that there is continuous and abundant lubrication.
- Check quality of tube.
- Check quality of threading oil (use ROTHENBERGER oil).
- Use the adapter for appropriate sizes (ut to 1.1/4").
- Check that the appropriate threading head is being used
(ROTHENBERGER, serie 600 or equivalent).
-Move the machine slightly upwards and downwards.
ENGLISH
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

71250

Tabla de contenido