Descargar Imprimir esta página

Technical Details - Sagola PACK 6000X Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
26/27

03. Technical details

Nominal temperature
range
Heat resistance of the
materials
Input materials at the
maximum
Minimum working
air flow
Maximum working air
flow (7 bar input)
Disconnection by
default
Thermal fuse
Maximum power
Power intensity fuse
(220-240V version)
Power intensity fuse
(110-130V version)
Frequency
Estimated weight
Dimensions
(length x width x height)
Community directive complied with
Explosive atmosphere (Atex)
(*) Non electric gun in explosion hazard areas (ATEX) must have the earthing connections and/or
static-free feed hoses.
Technical details
PACK 6000X AIR HEATER
De 20 °C a 70 °C
220 °C
7 bar
150 L/min
750 L/min
80 °C
216 °C
980 w
50 - 60 Hz
3.6 Kg
255 x 92 x 455 mm
10 x 3.6 x 18 "
ENGLISH
De 68 °F a 158 °F
428 °F
102 psi
5.3 cfm
26.5 cfm
176 °F
421 °F
1.3 HP
5 A
10 A
7.9 lbs
2014/34/UE
II 2G T4 x (*)

Publicidad