- That the programmed temperature value is within the allowed limits (up to 70°C).
- That in the event that one wishes to work with a value of temperature programmed above 50°C
one must use the appropriate protective measures (heat insulation), for the handling of the parts
and tools that may come into contact with the hot air. Especially the coupling of the hot air outlet
of the equipment, the spray gun or the application tool and the hoses (pipes).

9.2.1. Integrated safety devices

Thermal fuse
The equipment is fitted with a 216°C thermal fuse (ref.52350036), located in the hot air cham-
ber (No.08). This fuse protects the equipment against overheating caused by a malfunction or
wrong programming of the controller. It is intended to cut the power to the resistance when the
temperature limit is reached.
After it having been rendered inactive by reaching a temperature of 216°C it must be replaced.
Please contact SAGOLA's Technical Assistance Service (TAS).
Intensity fuse
The equipment is fitted with an intensity spike fuse, which protects all the equipment in the event
of high consumption above 5A (220-240V) ref.52350094 or 10A (110-130V) ref.52350095,
(short-circuit or malfunction of the resistance).
After it having been rendered inactive by reaching an intensity of 5A or 10A it must be replaced.
Please contact SAGOLA's Technical Assistance Service (TAS).
Disconnection due to lack of air circulation
The equipment team is fitted with a flow meter, which protects the resistance from overheating,
in the absence of cold air consumption and subsequent insufficient cooling of the resistance. It
ensures energy savings when there is no air consumption and protects it against undue starting
up (by error) of the equipment.
The trigger point of the flow meter is set to a value of 150 L/min. If malfunction of the operation
of the flow meter is suspected, please contact SAGOLA's Technical Assistance Service (TAS).
"Cold touch" heat insulation to the outside
The design and construction of the equipment, as well as the thermal insulation used, ensure
that the outer surfaces of the equipment are kept cold during operation, with the exception of the
compressed air coupling, which will be kept hot.
The temperature of the outer surfaces of the equipment shall in any event not exceed the tempe-
rature selected on the temperature controller.
If excessive heating of the outside surfaces of the equipment is detected, turn off the equipment
and check its condition.
Protection of the controls
The equipment is fitted with a protective cover with transparent glass that completely covers all
the temperature controller's controls, protecting these from dust, vapours and occasional spills
of liquids. At the same time it protects against erroneous programming by the unintentional pres-
sing of the temperature controller keys.
When programming the equipment, to prevent breakage, damage or loss, we recommend that
you fit the protective cover on the anchoring plate of the PACK 6000X AIR HEATER, in the groove
provided for this purpose.
ENGLISH