Descargar Imprimir esta página

Scope Of Delivery - Brita PURITY 450 Steam Manual De Instrucciones

Ocultar thumbs Ver también para PURITY 450 Steam:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
4 Installation
Caution: Prior to installation read the Technical Data (Chapter 10) and the Operating
!
and Safety Information (Chapter 3). After storage and transport below 0°C the product
must be stored in the open original packaging for at least 24 hours at the stated ambient
temperatures (Chapter 10) for operation.

4.1 Scope of Delivery

Prior to installation, remove the entire delivery scope from the packaging and check that
the following articles are present:
1 x Pressure Vessel
1 x Pressure Vessel Lid
1 x Filter Cartridge
1 x Manual
1 x Carbonate Hardness Test
1 x Sticker for Service Pass (orange)
1 x Reducer 1"– 3/4"
If part(s) of the delivery scope are missing, please contact your local BRITA Offi ce
(see back of cover).
4.2 Assembly of the pressure vessel and the pressure vessel lid
1
3
2
Stand on the kick loops
Lift the pressure vessel
dle
is over the kick loops
11
Remove the transport protective cap
Check the O-ring seal of the fi lter cartridge
the groove, dirt and damage. Note: The cartridge seat has been
lubricated with food-safe lubricant at the factory.
Stand on the kick loops
vessel lid
on the pressure lid
3
marking on the lid handle
Press the pressure vessel lid
lock engages
.
8
with both feet.
9
and turn it clockwise until the mantle han-
1
.
9
from the fi lter cartridge.
12
2
with both feet and place the pressure
9
. The positioning of the arrow
1
must line up with the "INSERT" groove.
14
down and turn clockwise until the
3
for correct seat in
15

Publicidad